- Home >
- Product >
- VENTILATOR >
- LTD Portable-Oxygen-concentrators
LTD Portable-Oxygen-concentrators
Product
Product Name:
LTD Portable-Oxygen-concentrators
LTD Portable-Oxygen-concentrators
Detailed Introduction:
Portable-Oxygen-concentrators
24 Hours Portable Air Purifier With Handle Household AC110V/220VNew
Key Specifications/Special Features:
Quick Details
Instrument classification:Class II
Warranty:1 YEAR
After-sale Service:Return and Replacement
Product name:Oxygen Concentrator
Function:Health Care
Application:Rehabilitation Centre
Color:White
Feature:Breathable
Material:ABS
More Products
Ventilator
portable ventilator / icu ventilator / oxygen ventilator Positive Airway Pressure Device .Mobile Bi-level for hospital 1. Maximum inhale pressure 30cmH2O, with separate humidifier, better humidification2. With ST and target tidal volume mode settings3. Fast rise time4. Normal inhalation intensity, respiration rate is 54 times / min, and each exhalation triggers the ventilator perfectly. Easily keep in sync5. Good synchronization with big flow Technical parameters of mobile bi-level PAP device• 1. Scope of application:For adult patients with ARDS, hypoventilation syndrome, for bi-level non-invasive ventilation in a hospital or home.• 2. the main function: 1. Different treatment options can be provided according to patients’ needs, from CPAP to S, T, S / T, VGPS five modes。2. Adjustable trigger sensitivity.3. Real-time monitoring and recording of blood oxygen saturation.4. alarm function.5. Record function (SD card).6. Maximum leak compensation function. 60L/min7. Waveform display in screen :Time&pressure, time&flow8. Medical use separate humidifier, better humidification and heating9. with Trolley, easy to move the device.• 3. the key technical parameters: 1. 1. Working mode: CPAP, S, T, ST, VGPS.2. 2. Ventilation parameters:• 2.1 Inspiratory pressure: 4-30 cmH2O (0.5 cmH2O interval)• 2.2 Expiratory pressure: 4-30 cmH2O (0.5 cmH2O interval)• 2.3 Treatment pressure: 4-20 cmH2O (in CPAP mode, 0.5 cmH2O interval)• 2.4 Delayed boost: 0-45 minutes (interval of 5 minutes)• 2.5 Breathing frequency: 5-50 times / minute (interval 1 time / minute)• 2.6 Breathing ratio: 10-70% (interval of 1%)• 2.7 Rise time: 1-5 steps (1 step interval, 1 step rises fastest, 5 steps rises most slowly)• 2.8 Inhalation sensitivity: 1-5 steps (1 step interval, 1st step triggers fastest, 5th step 1st step triggers slowest)• 2.9 Exhalation sensitivity: 1-5 (1 interval, the 1st trigger is the fastest, 5th and 1st the slowest)• 2.10 Tidal volume: 50-1500ml (effective in VGPS mode, interval 50ml)• 3. VGPS(same with AVAPS,can set Target tidal volume)mode:• 3.1 Maximum IPAP value adjustable range: 4-30 cmH2O• 3.2 Adjustable range of minimum IPAP value: 4-30 cmH2O• 3.3 EPAP value adjustable range: 4-30 cmH2O• 3.4 Target Tidal Volume: 50-1500ml• 4. Display range of monitoring setting parameters:• 4.1 Respiratory waveform can be displayed;• 4.2 Current mode: CPAP, S, T, ST, VGPS• 4.3 Inspiratory pressure: 4-30 cmH2O• 4.4 Expiratory pressure: 4-30 cmH2O• 4.5 Breathing frequency: 5-50 times / minute• 4.6 Breathing ratio: 10-70%• 4.7 Air leakage: 20-99.9lpm• 4.8 Tidal volume: 50-1500ml• 4.9 minute ventilation: 0-50lpm• 4.10 Blood oxygen saturation: 70-100%• 4.11 Pulse rate: 25-250bpm• 4.12 Delay boost: 0-45 minutes• 5. Alarm items:• 5.1 High pressure sound prompt: Turn on / off sound prompt• 5.2 Low minute ventilation sound prompt: Turn on / off sound prompt, can be set to 1-10L (interval 1L)• 5.3 Air leakage sound prompt: on / off• 5.4 Power off sound prompt: on / off• 5.5 Choking voice prompt: On / off, choking time can be set to 10-40 seconds (interval of 5 seconds)• 5.6 Low Tidal Volume Sound Prompt: On / Off, Set Tidal Volume Value Range 50-500ml ((Interval 50ml))• 6. Specifications• 6.1 Weight: about 1500g• 6.2 Operating temperature: 5-35 ° C• 6.3 Relative humidity: 10% -90%• 6.4 Power supply: input is AC 100-240V, 50-60Hz, 1.8A Max; output: DC 24V, 3.33A. If you are interested in any product, please contact us as soon as possible.LTD Factory Direct Supply Oxygen Concentrator 1-7L Home Medical Use High Purity New
Factory Direct Supply Oxygen Concentrator 1-7L Home Medical Use High Purity New Key Specifications/Special Features:Home use oxygen concentrator 1-7LDE-1AWFlow Range: 1-7LPM ;Pressure : (30-60)kPa;Purity:93%±3%@1-7LPM;Power consumption : 120W(average);Noise: 45dB(A); Voltage: 115V±10% / 60HZ±1HZ -245V±10% / 50HZ±1HZ;Continue working time : 24hours *7 days; Dimension: 39.5*23.7*45.5cm ; N.W:7.5KGWarranty : 12months for complete device , 36 months for compressor ;H.S code : 9019200090 Shipping Information:•FOB Port:China (Mainland) •Lead Time:3 - 5 days •HTS Code:9019.20.00 90 •Dimensions per Unit:39.5 × 23.7 × 45.5 Centimeters •Weight per Unit:7.2 Kilograms •Units per Export Carton:1LTD High-Flow Nasal Cannula (HFNC)Treatment
High-Flow Nasal Cannula (HFNC) Treatment High-Flow Nasal Cannula (HFNC) TreatmentHigh-Flow Nasal Cannula (HFNC) Treatment is a non-invasive respiratory support therapy that delivers warm, humidified, oxygen-enriched air to patients, usually using a nasal cannula. Typically used in spontaneously breathing patients who typically require oxygen at higher flow rates. It can provide respiratory support of patients with acute hypoxemic respiratory failure and prevent subsequent intubation when used correctly. This greatly enhances patient comfort and ease of use. Life-saving treatment with HFNC TherapyWatch this video to learn more about how HFNC:• Leads to improvements in oxygenation1, respiratory rate2, dyspnea3 and patient comfort4• Helps patients recover faster following extubation1• Translates to improved outcomes and shorter ICU stays4Play video How to useWatch this video to learn more about how to use the Dräger Hi-Flow Star HFNC Solution HFNC.Play videoCOVID-19 UpdatesAccording to WHO 2020, “Data from China suggests that although the majority of people with COVID-19 have a mild illness (40%) or moderate illness (40%); about 15% of them have a severe illness requiring oxygen therapy, and 5% will be critically ill requiring intensive care unit treatment.”5"COVID-19 treatment health-care facilities should be equipped with pulse oximeters, functioning oxygen systems including single-use oxygen delivery interfaces.Oxygen therapy is recommended for all severe and critical COVID-19 patients, with low doses ranging from 1-2 L/min in children and starting at 5 L/min in adults with nasal cannula, moderate flow rates for use with venturi mask (6-10 L/min); or higher flow rates (10-15 L/min) using a mask with reservoir bag. In addition, oxygen can be delivered at higher flow rates and in higher concentrations, using high-flow nasal cannula (HFNC) devices, non-invasive ventilation (NIV) and invasive ventilation devices.”6 Dräger Hi-Flow Star HFNC SolutionThe standard can be customized with the products shown below. Trolley Oxymixer Blender MR850 Humidifier Hi-Flow Star Circuit Hi-Flow Star CannulaLTD Medical Grade Portable Oxygen Concentrator with Atomization version
Medical Grade Portable Oxygen Concentrator with Atomization Key Specifications/Special Features:Specifications/Special Features:Product Model: 7F-5(W)1.Power 400VA2.The oxygen flow rate: 5L/MIN3.After-sales: The whole machine is guaranteed for one year and thecompressor for three years4.The main raw material UOP Molecular sieve5.Noise The measurement standard values 52db(A)6.Net Weight: 19KGS7.Oxygen concentrations: Whenis 0.5-5l/min, canbe 93%+-3%LTD Ooxygen flow meter
Oxygen flow meter