Blood Pressure Monitor, Blood Pressure Monitor Wrist Type, Blood Pressure Monitor Arm Type, Blood Glucose Monitoring System, Blood Glucose + Pressure Monitor, Pulse Watch, Ear Thermometer, Forehead Thermometer, HERS MEDICAL 4 In1 Multi-Infrared Thermometer , Digital Thermometer, Digital Thermometer For Animal Use, Pacifier Thermometer, Babycare, Aquarium Thermometer, Digital Alcohol Detector, Kitchen Scales, Body Fat Scales, Body Fat Analyzer,  Measurement Thermometer             
Product ID: YS-932

HERS MEDICAL Blood Pressure Monitor Wrist Type

To inquire, select products on and click 

Features:

Smart Logic

Vertical LCD Display

Option Functions: 42 sets or 85 Sets Memory

Measuring Range 20 ~ 300 mmHg
40 ~ 200 pulse/minute
Resolution 1 mmHg
Accuracy +/- mmHg or 2% (pressure)
+/- 5 % of readings (pulse rate)
Measuring
Method
Oscillometric method
Operation Key 4 Keys: I/O.M.U.T
Display Liquid Crystal Display
Inflation Micro rolling pump
Exhaust Electrical Solenoid valve
Memory 2x50, 3x33, 4x25, or 5x20
Time Displaying date, time and year
Operation
Condition
Temperature: 10oC ~ 35oC(50oF ~ 90oF)
Relative Humidity: 10% ~ 83%
Storage
Condition
Temperature: -25oC ~ +60oC (-13oF ~ +140oF)
Relative Humidity: 10% ~ 83%
Power Source 3Vdc; "AAA" type battery x 2
Battery Life Around 250 measurements(alkaline batteries)
Low Battery
Indication
Replace the batteries if the low battery indicator
appears
Auto Off Automatically after 150 seconds without operation
Size 78 x 72 x 30 mm
Weight 130g w/ batt.
Standard Complies with EN 1060-1, -3 and ANSI/AAMI SP10A-1996
   

For your clinical test measurement must issue  DIN Standard committee for non-invasive sphygmomanometers.

 DIN 58130  5.6 Test Method N6

DIN58130 ENGLISH  

 

 If you test measurement one time must be rest 3 minute, Would you please can not continuous test measurement

Or Please rest for three minutes

  

Periodical Re-calibration:

Sensitive measuring devices must from time to time be checked for accuracy,

We therefore recommend a periodical inspection of the static pressure display every 2 years. Your specialist dealer would be pleased to provide more extensive information about this.

Calibration is recommended every two years

Specifications are subject to change for improvement without notice